{"product_id":"whatsminer-p566z-p564z-power-supply-psu-m63-m63s-hydro","title":"Whatsminer P566Z P564Z PSU 10000W – M63 M63S M63S+ M63S++ M65S+ Hydro Miner Power Supply","description":"\u003ch2\u003eWhatsminer P566Z \/ P564Z Power Supply 10,000W – For M63 \u0026amp; M65S+ Hydro Miners\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eWhatsminer P566Z and P564Z\u003c\/strong\u003e are \u003cstrong\u003ehigh-voltage DC power supplies\u003c\/strong\u003e designed by MicroBT specifically for \u003cstrong\u003ehigh-hashrate hydro (water-cooled) miners\u003c\/strong\u003e: \u003cstrong\u003eWhatsminer M63, M63S, M63S+, M63S++ and M65S+\u003c\/strong\u003e. The P566Z (P\/N \u003cstrong\u003eP566Z-BC-42-10000-A-V01\u003c\/strong\u003e) delivers \u003cstrong\u003e10,000 W\u003c\/strong\u003e on a \u003cstrong\u003e42 V DC\u003c\/strong\u003e rail from a \u003cstrong\u003e380–480 VAC three-phase\u003c\/strong\u003e input rated at up to \u003cstrong\u003e17 A\u003c\/strong\u003e. Both PSUs are engineered for \u003cstrong\u003e24\/7 full-load duty\u003c\/strong\u003e with integrated \u003cstrong\u003ewater cooling\u003c\/strong\u003e, wide input bandwidth and a complete protection suite — the standard MicroBT replacement for failed units and the OEM fit for new builds.\u003c\/p\u003e\n\u003ch3\u003eWhy M63-Class Hydro Miners Need a 3-Phase High-Voltage PSU\u003c\/h3\u003e\n\u003cp\u003eThe M63 family operates close to \u003cstrong\u003e10 kW per unit\u003c\/strong\u003e at the wall — a load that single-phase 220 V infrastructure cannot service efficiently. Three-phase 380–480 VAC supply spreads current across all three lines, lowering per-conductor heat, reducing copper cross-section and keeping breaker sizing realistic at the rack level. The P566Z is sized for that scenario: 17 A per phase at 480 V three-phase yields the full 10 kW the M63S++ requires, with headroom for the brief inrush at miner power-on.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Water Cooling for Hydro Mining Duty Cycles\u003c\/h3\u003e\n\u003cp\u003eAir-cooled PSUs throttle, derate or trip when surrounding farm temperatures climb. The P566Z and P564Z are built into the hydro coolant loop, so the same water that cools the hashboards also pulls heat from the PSU's transformer, switching stage and output rectifiers. This is the only way to sustain 100% load 24\/7 without thermal cycling — the failure mode that kills capacitors and MOSFETs in air-cooled supplies tasked with hydro-class wattage. Wide input bandwidth (380–480 VAC) keeps the PSU stable across regional grid voltages without manual taps or external transformers.\u003c\/p\u003e\n\u003ch3\u003eFull Protection Suite for High-Wattage Mining\u003c\/h3\u003e\n\u003cp\u003eBoth the P566Z and P564Z integrate \u003cstrong\u003eovervoltage (OVP), undervoltage (UVP), overcurrent (OCP), short-circuit (SCP), overheat (OTP)\u003c\/strong\u003e and \u003cstrong\u003eautomatic shutdown\u003c\/strong\u003e on abnormal events. At 10 kW, an unprotected fault propagates fast — a primary-side MOSFET failure can take out the hashboards downstream. The PSU's sense logic isolates the load before damage spreads, which is one of the main reasons MicroBT specifies these units for the M63 family rather than allowing third-party substitutes.\u003c\/p\u003e\n\u003ch3\u003eWhen to Replace a P566Z \/ P564Z PSU\u003c\/h3\u003e\n\u003cp\u003eCommon failure modes in field deployments: the miner refuses to power on after a grid event, hashboards disappear from the dashboard one by one as the 42 V rail droops under load, the PSU triggers OTP shutdowns even with normal coolant flow, or there is an audible buzz \/ pop following an input spike. At 10 kW, board-level repair on the bench rarely beats a swap-out — input-side MOSFETs and main capacitors that fail catastrophically take output rectifiers with them, and a known-good P566Z restores full hash rate without diagnostics downtime.\u003c\/p\u003e\n\u003ch3\u003eInstallation \u0026amp; Mains Notes\u003c\/h3\u003e\n\u003cp\u003eConfirm your facility delivers \u003cstrong\u003e380–480 VAC three-phase\u003c\/strong\u003e service with at least \u003cstrong\u003e17 A per phase\u003c\/strong\u003e available on a properly rated breaker. Disconnect mains and depressurise the cooling loop before swapping the PSU. Mount the unit, connect the coolant inlet\/outlet through quick-connect fittings, then attach the DC output harness to the hashboards and the auxiliary connector to the control board. Re-pressurise the coolant loop, check for leaks at every joint, and only then re-energise the AC input. Verify hash rate ramps to target and that PSU temperature stabilises within the first hour of operation.\u003c\/p\u003e\n\u003ch4\u003eWhatsminer P566Z Power Supply Specifications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; padding: 6px 12px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"text-align: left; padding: 6px 12px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eP566Z-BC-42-10000-A-V01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eOutput Power\u003c\/td\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003e10,000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003e42 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003e380–480 VAC, three-phase (3~)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eInput Frequency\u003c\/td\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eMax Input Current\u003c\/td\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003e17 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eCooling\u003c\/td\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eIntegrated water cooling (hydro loop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eProtections\u003c\/td\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eOVP, UVP, OCP, SCP, OTP, automatic shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eWhatsminer M63, M63S, M63S+, M63S++, M65S+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eCompanion Model\u003c\/td\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eP564Z (same family, same protections, same compatibility — confirm exact spec match before ordering)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eMicroBT (Whatspower)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eCondition\u003c\/td\u003e\n\u003ctd style=\"text-align: left; padding: 6px 12px;\"\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eRelated Whatsminer M63 Hydro Parts \u0026amp; Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/whatsminer-cb6-v5-control-board-m33s-m33s-m53-m53s-m53s-m63-m63s-hydro-miners\"\u003eWhatsminer CB6 V5 Control Board – M33s \/ M53 \/ M63 Hydro\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/whatsminer-hydro-miner-data-cable-16pin-m33s-m33s-m53-m53s-m63-m63s\"\u003eWhatsminer Hydro 16-Pin Data Cable – M63 Series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/double-seal-quick-connector-for-asic-miner-water-cooling-tubes\"\u003eDouble-Seal Quick Connector – ASIC Miner Water Cooling Tubes\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/lian-li-8kw-asic-water-cooling-row-efficient-heat-dissipation-for-whatsminer-antminer\"\u003eLian Li 8 kW Water Cooling Row – Whatsminer \/ Antminer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDeploying or maintaining an M63 \/ M65S+ hydro fleet? \u003ca href=\"mailto:contact@lys-sz.com\"\u003eContact us at contact@lys-sz.com\u003c\/a\u003e for P566Z \/ P564Z pricing, paired-PSU bundles and full hydro-loop replacement parts.\u003c\/p\u003e\n\u003cp\u003eWorldwide shipping from our Shenzhen warehouse.\u003c\/p\u003e","brand":"LYS Shenzhen","offers":[{"title":"P566Z","offer_id":45494239330483,"sku":null,"price":668.0,"currency_code":"USD","in_stock":true},{"title":"P564Z","offer_id":45494239363251,"sku":null,"price":668.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0627\/6710\/4179\/files\/whatsminer-p566z-psu-10000w-m63-hydro-front.webp?v=1778116323","url":"https:\/\/lys-sz.com\/products\/whatsminer-p566z-p564z-power-supply-psu-m63-m63s-hydro","provider":"LYS Shenzhen","version":"1.0","type":"link"}