The MKP62 305V X2 2.2µF (225K) film capacitor is the across-the-line (X2-class) safety capacitor sitting in the AC input EMI filter of mining PSUs. Rated for direct connection between the live and neutral conductors at 305VAC, it suppresses high-frequency switching noise generated by the PSU's primary stage from re-entering the mains, and rejects mains-borne transients from coupling into the PSU. X2-class construction is mandatory by safety standard for this position — a regular ceramic or electrolytic cannot legally substitute. A failed X2 capacitor causes EMI compliance failure, mains buzzing, and in extreme cases a controlled fail-safe open that takes the input filter offline.
How the X2 Capacitor Fails
X2 film capacitors are designed to fail safe — they degrade open rather than short, which is why they're allowed across the AC line. After years of mains-transient stress, surges, and humidity exposure, the metallised film inside slowly self-heals away from defects, gradually losing capacitance. Symptoms: increased EMI on conducted-emissions tests, audible buzz at mains frequency in the PSU, and on the bench a measured capacitance well below the 2.2µF rating. Mining PSUs run hot inside crowded enclosures, so this drift happens faster than in consumer gear.
Replacement Procedure
Disconnect the PSU from mains and bleed the bulk capacitors (5 minutes minimum, or use a bleed resistor). Identify the failed MKP62 — usually a yellow or red rectangular box mounted directly across the AC input traces, near the input fuse and the common-mode choke. Desolder the old part, clean the through-hole pads, and fit the new MKP62 305V X2 2.2µF in the same orientation. Critical: only fit a part with X2 marking — never substitute a non-safety capacitor in this position. Visually verify the markings match before powering on.
MKP62 305V X2 Specifications
Parameter
Value
Part Number
MKP62 305V X2 (225K marking = 2.2µF, K tolerance)
Capacitance
2.2µF
Voltage
305VAC (X2 across-the-line rating)
Tolerance
±10% (K marking)
Safety Class
X2 (live-to-neutral, fail-safe open)
Function
EMI filter / mains interference suppression
Substitution Rule
X2-class only — never substitute a non-safety capacitor
Stocking MKP62 X2 capacitors for a PSU repair line? Contact us at contact@lys-sz.com for volume pricing. Worldwide shipping from our Shenzhen warehouse.
📦 Shipping & Customs⌄
🇺🇸🇪🇺 USA & European Union (DDP): Orders are delivered DDP. All customs duties, import taxes, and fees are included — no additional charges on delivery.
🌍 Rest of world: Orders ship from China. Depending on your country, local customs authorities may apply import duties or taxes.
Get dedicated B2B pricing on this part and across our full catalog —
quote response within 24 hours, payment by T/T USD bank wire,
and DDP delivery available for US & EU customers (and other lanes on request).
Volume tiers
DDP for US & EU
T/T USD wire
24h response